R.I.P. CRI

It’s been a little over two years since the IES released TM-30-15 IES Method for Evaluating Light Source Color Rendition.  In that time TM-30 has seen growing support in the industry and a growing body of evidence for its accuracy and usefulness.  We’ve nearly reached the moment when we can all agree that it’s time to retire CRI and fully adopt a modern, accurate system of measuring and describing the color rendering of light sources.  What’s wrong with CRI?  Quite a bit, so if you’re not up to date on the issue here’s an overview.

In 1948 The CIE first recommended a color rendering index based on a method developed in 1937.  The 1937 method is a fidelity metric (that is, it compares a test light source to a reference light source) that divides the spectrum into eight bands and compares each band to a full spectrum radiator.  In 1965 the CIE finally adopted CIE 13-1965 Recommended method of measuring and specifying color rendering properties of light sources, based on a test color sample method, what today we call CRI Ra or just CRI.  From the start it was apparent that there were problems.  In 1967 a committee was established to correct for adaptive color shift.  Other problems were uncovered, and in 1974 a formal update was published.  Errors were uncovered in the 1974 edition, resulting in a third version in 1994, which is the version we use today.

So far, so good.  Errors are discovered in the method used and are eventually corrected, so what’s the fuss?  The fuss is that the corrections were minor compared to the scope of the errors, and 23 years after the last correction we still don’t have an accurate, up to date system.  In the early 1990s a proposal to update the formula and test color samples failed to gain consensus.  Two subsequent attempts to improve the metric also closed without adoption.  The current problems, as described in the 2011 IES Lighting Handbook, 10th Edition include:

  • Averaging the color shifts of the eight test colors says nothing about the rendering of any single sample.  A large error in one color can be masked by accurate rendering of the other samples.
  • The test color samples are all of moderate saturation so the index doesn’t reveal color shifts in saturated colors.  In addition, the test colors are not evenly distributed through the color space or the spectrum, so light source spectra can be engineered to score higher than visual observation would indicate.
  • The color space used, the 1964 UCS chromaticity diagram, is no longer recommended for any other use.
  • All chroma shifts are penalized, even though research shows that moderately increasing chroma is desirable in many applications.
  • The chromatic adaptation used has been shown to perform poorly and is no longer recommended for any other use.
  • A single number index gives no information about the direction or extent of color shift for any particular color or color range.

Why haven’t these problems been corrected in the past 23 years?  I’m told that there are two issues.  The small issue is that competing scientific interests on the committee advocate new metrics that they’ve developed as a replacement or supplement to CRI.  The larger problem is that manufacturers on the committee don’t want to see any changes that would reduce the CRI of any of their lamps.  From their perspective, it’s better to have a high score on an inaccurate test than a low score on an accurate one.  It seems that internal politics has been preventing updates, corrections, and improvements.

Although many other color rendering metrics have been proposed over the years, none has been adopted by CIE, which has the most significant voice on this issue.  The result is that the sole internationally accepted metric, which has also been written into product specifications and into codes, is CRI.  That began to change in 2015 with the introduction of TM-30. I’ll have more to say about TM-30 in future posts, but for now let’s agree that CRI Ra is broken and CIE is in no hurry to fix it.  A better system exists, and our industry should adopt it.

The Myth of the Irrelevant Lighting Designer

Kevin Willmorth has a long and interesting article on his blog in which he argues for the recognition of professional lighting designers and what a professional lighting designer is and is not.  The post echoes Chapter 1 of Designing With Light, and many of the things I’ve written here, including promoting the lighting design profession, the value of professional lighting design, the need for projects to use a professional lighting designer (here, here and here),  those other than professional lighting designers making design decisions, and poor documentation of LED products by manufacturers, among other topics.  I don’t have much to add to Kevin’s post, except to say that it’s well worth reading.

IES Lighting Terms and Definitions Now Online

ANSI/IES RP-16 Nomenclature and Definitions for Illuminating Engineering has long been one of the two major documents defining terms related to lighting design (the other is CIE ILV: International Lighting Vocabulary).  RP-16-10 (the 2010 version of the Recommended Practice) is now available online as a searchable database.  From the first page you can click on terms to see the definition and you can also search by keyword.  If you don’t already own RP-16 bookmark this now!

IES Disagrees With AMA on Night Time Outdoor Lighting

Last year the AMA issued Policy H-135.927 Human and Environmental Effects of Light Emitting Diode (LED) Community Lighting, which recommended, among other things, that LED outdoor lighting should have a CCT of 3000 K or below.  The AMA made this recommendation thinking that lower correlated color temperatures contain less blue light, which can disrupt circadian rhythms.

Today the IES issued a Position Statement disputing that recommendation, noting that CCT

is inadequate for the purpose of evaluating possible health outcomes; and that the recommendations target only one component of light exposure (spectral composition) of what are well known and established multi-variable inputs to light dosing that affect sleep disruption, including the quantity of light at the retina of the eye and the duration of exposure to that light. A more widely accepted input to the circadian system associated with higher risk for sleep disruption and associated health concerns is increased melanopic content, which is significantly different than CCT. LED light sources can vary widely in their melanopic content for any given CCT; 3000 K LED light sources could have higher relative melanopic content than 2800 K incandescent lighting or 4000 K LED light sources, for example.

Follow the link to read the entire Position Statement.  Blue light hazard, light’s impact on circadian rhythms and overall health, and related topics are a hot area of research.  We’re learning more all the time, but we don’t yet know enough to apply circadian lighting to every situation.  Outdoor and street lighting are among the areas where research is not yet conclusive.

A New Report on LED Color Shift

Like other lighting technologies, the color or chromaticity of light emitted by an LED can shift over time.  To address the challenge of developing accurate lifetime claims, DOE, together with the Next Generation Lighting Industry Alliance, formed an industry working group, the LED Systems Reliability Consortium (LSRC).  A new LSRC report, LED Luminaire Reliability: Impact of Color Shift, focuses on chromaticity. The purpose of the new report is not to define limits for specific applications, but rather to enable a better understanding of how and why color shifts, and how that impacts reliability.  Download it and take a look.